Revision as of 13:01, 11 December 2021

UNIT
Device Interactions Port Description Connection Diagram

Poly-Liar Unit

  • Galvanic Skin Response Sensor
  • Heart Beat Detection Sensor
  • Respiration Detection Sensor
  • Skin Temperature Sensor
Pin Mapping
Line # Device Signal Function
1 3.3V Power
2 GND Power
3 Tone Controller I2C-SDA
4 Tone Controller I2C-SCL
5 Respiration Detection Analog
6 Skin Temperature Analog
7 Pulse Detection Analog
8 GSR Signal Analog

This Amazing, Affordable, Earth Changing Device, for which no endorsement is to be inferred, is designed in conflict.

Tracking Goggles External Unit

Components and Materials

Items
Device Use

ATTiny85 Tone Token

Provide audio signal to user and external unit id to main device

Breathing Sensor Type B component

Breathing Sensor Type B

Breathing Sensor Type B component

thunmbnail
thunmbnail

RJ45 Port

Provides connectivity to Main Unit

Cabling

Electrical wiring and as inner telescoping tube in chest band assembly

Flexible Tubing

Chest band assembly as exterior telescoping tube to set tightness for breathing sensor

Copper Tape

Conductive contact with skin

Foam Sheet

Flexible finger wraps

Project Box (variants)

Enclosure for control box

Sensor

Items
Device Description Interface
TMP36 Voltage Output Temperature Sensors Analog Voltage Output
IR Pulse Detector Analog Voltage Output

TCRT5000

IR Reflectance Sensor

Analog Voltage Output

GSR Circuit Analog Voltage Output

Wiring

Sub-Assembly Elements Schematic
  • Galvanic skin Response Sensor
  • TL074 Op-Amp

ATTiny85 Tone Token

  • ATTINY85
  • Piezo Speaker
  • Local Reset Button
  • IR Pulse Sensor
  • Breathing Sensor Type B
  • ATTiny85 Tone Token
  • Breathing Sensor Type B
  • Skin Temperature Sensor
  • Pulse Detector Sensor
  • Galvanic skin Response Sensor

Assembly

Breathing Sensor Type B

Sub-Assembly Elements

Breathing Sensor Type A

Sliding Plunger

Renders
  • Two Compression Brackets
  • IR Pulse Sensor used as Distance Compression Sensor Inside
  • BLUE - Compression Sensor Orientation Stabilizer
  • YELLOW - Compression Sensor Bracket Oriented as Lower
  • GREEN - Compression Sensor Bracket Oriented as Upper
  • CYAN - Telescoping Tube Cradle
  • RED - Rubber Band (Provides Flexing of Compression Sensor Brackets)
  • VIOLET - Fastner (Holds Exterior Telescoping Tube Secure and Allows Inner Tube to Move)
  • SEMI-TRANSPARENT GREEN - Outer Telescoping Tube (Inner Telescoping Tube visible)

Cradle

Orientation and Stabilizing Base

IR Pulse Sensor

Build

Return

Pseudo-Medical Monitor