Pseudo-Medical Monitor Hand-Held External Unit Design: Difference between revisions

From LVL1
Jump to navigation Jump to search
Line 65: Line 65:


{|class="wikitable"
{|class="wikitable"
!colspan="3"|Items
!colspan="2"|Items
|-
|-
|Device
|Device
Line 73: Line 73:
|
|
[[File:JAC MED MON MOMENTARY SWITCH PART.jpg|left|thumbnail|x200px]]
[[File:JAC MED MON MOMENTARY SWITCH PART.jpg|left|thumbnail|x200px]]
| Momentary Switch
Momentary Switch
|
|
Provide user response
Provide user response
Line 79: Line 79:
|
|
[[File:JAC MED MON VIBRATING MOTOR PART.jpg|left|thumbnail|x200px]]
[[File:JAC MED MON VIBRATING MOTOR PART.jpg|left|thumbnail|x200px]]
| Vibrating Motor
Vibrating Motor
|
|
Provide sensory input to user
Provide sensory input to user
Line 85: Line 85:
|
|
[[File:JAC MED MON ATTINY85 TOKEN BARE.jpg|left|thumbnail|x200px]]
[[File:JAC MED MON ATTINY85 TOKEN BARE.jpg|left|thumbnail|x200px]]
| ATTiny85 Token
ATTiny85 Token
|
|
Identify External Unit to Main Unit
Identify External Unit to Main Unit
Line 91: Line 91:
|
|
[[File:JAC_MED_MON_RJ45_SINGLE_BARE_PART.jpg|left|thumbnail|x200px]]
[[File:JAC_MED_MON_RJ45_SINGLE_BARE_PART.jpg|left|thumbnail|x200px]]
| Single RJ45 Port
Single RJ45 Port
|
|
Connection to Main Unit
Connection to Main Unit
Line 97: Line 97:
|
|
[[File:JAC MED MON FOAM SHEET MATERIAL.jpg|left|thumbnail|x200px]]
[[File:JAC MED MON FOAM SHEET MATERIAL.jpg|left|thumbnail|x200px]]
| Foam Sheet
Foam Sheet
|
|
Outer Cover
Outer Cover
Line 103: Line 103:
|
|
[[File:JAC MED MON COPPER TAPE MATERIAL.jpg|left|thumbnail|x200px]]
[[File:JAC MED MON COPPER TAPE MATERIAL.jpg|left|thumbnail|x200px]]
| Copper Tape
Copper Tape
|
|
Conductive surface for Velostat sheet readings
Conductive surface for Velostat sheet readings
Line 109: Line 109:
|
|
[[File:JAC_MED_MON_POLYCARBONATE_TUBE_PART.jpg|left|thumbnail|x200px]]
[[File:JAC_MED_MON_POLYCARBONATE_TUBE_PART.jpg|left|thumbnail|x200px]]
| Polycarbonate Tube (Size/Length/Diameter/Thickness varied according to use)
Polycarbonate Tube (Size/Length/Diameter/Thickness varied according to use)
|
|
Grip Structure
Grip Structure

Revision as of 17:22, 10 December 2021

UNIT
Device Interactions Port Description Connection Diagram

Hand-Held Grip and Reflex Sensor

  • Steady Hold
  • Grip Strength
  • User Response Switch
  • Vibration Generation
Pin Mapping
Line # Device Signal Function
1 3.3V Power
2 GND Power
3 MPU6050/ATTiny85 Token I2C-SDA
4 MPU6050/ATTiny85 Token I2C-SCL
5 MPU6050-INT GPIO
6 Vibrating Motor I/O GPIO
7 Momentary Push Button GPIO
8 Grip Sensor Analog

This Amazing, Affordable, Earth Changing Device, for which no endorsement is to be inferred, is designed as a shot in the dark.

Hand-Held Grip and Reflex External Unit

Components and Materials

Items
Device Name Use

Momentary Switch

Provide user response

Vibrating Motor

Provide sensory input to user

ATTiny85 Token

Identify External Unit to Main Unit

Single RJ45 Port

Connection to Main Unit

Foam Sheet

Outer Cover

Copper Tape

Conductive surface for Velostat sheet readings

Polycarbonate Tube (Size/Length/Diameter/Thickness varied according to use)

Grip Structure

Sensors

Sensors
Device Description Interface

MPU6050 6 DOF Micro Electro-Mechanical Systems (MEMS)

3-axis Accelerometer and 3-axis Gyroscope I2C Address 0x68 or 0x69

Velostat Pressure-Sensitive Conductive Sheet

Resistance measurement between points Analog Voltage Output

Wiring

Sub-Assembly Elements Schematic

Hand Held Unit PCB

  • MPU6050
  • Vibrating Motor Circuit
  • Velostat Wrap
  • Copper Rings
  • Momentary Switch
  • ATTiny85 Token

Assembly


Build




Return

Pseudo-Medical Monitor