Pseudo-Medical Monitor EKG External Unit Design: Difference between revisions

From LVL1
Jump to navigation Jump to search
No edit summary
No edit summary
Line 58: Line 58:
|
|
[[File:JAC_MED_MON_EKG_CONNECTION_DIAGRAM.jpg|left|thumbnail|x200px]]
[[File:JAC_MED_MON_EKG_CONNECTION_DIAGRAM.jpg|left|thumbnail|x200px]]
|
[[Pseudo-Medical Monitor EKG External Unit Design]]
|}
|}



Revision as of 15:39, 10 December 2021

UNIT
Device Interactions Port Description Connection Diagram

EKG-Respiration Unit

  • ATTiny85 NeoPixel Token
  • EXG BIO AMP Unit
  • Respiration Detection Sensor with Amplifier
  • Harness
  • RJ45 Socket Breakout Board
Pin Mapping
Line # Device Signal Function
1 3.3V Power
2 GND Power
3 NeoPixel Controller I2C-SDA
4 NeoPixel Controller I2C-SCL
5 Respiration Detection Analog
6 Respiration Detection Adjust Analog
7 N/C Analog
8 Heart Beat Signal Analog


Return

Pseudo-Medical Monitor