EKG-Respiration Unit
|
* ATTiny85 NeoPixel Token
* EXG BIO AMP Unit
* Respiration Detection Sensor with Amplifier
* Harness
* RJ45 Socket Breakout Board
|
{|class="wikitable"
!colspan="4"|Pin Mapping
|-
|Line #
|Device Signal
|Function
|-
|1
|3.3V
|Power
|-
|2
|GND
|Power
|-
|3
|NeoPixel Controller
|I2C-SDA
|-
|4
|NeoPixel Controller
|I2C-SCL
|-
|5
|Respiration Detection
|Analog
|-
|6
|Respiration Detection Adjust
|Analog
|-
|7
|N/C
|Analog
|-
|8
|Heart Beat Signal
|Analog
|}
|
[[File:JAC_MED_MON_EKG_CONNECTION_DIAGRAM.jpg|left|thumbnail|x200px]]
|
[[Pseudo-Medical Monitor EKG External Unit Design]]
|-
 


== Return ==
== Return ==


  [[Pseudo-Medical Monitor]]
  [[Pseudo-Medical Monitor]]

Revision as of 15:38, 10 December 2021

|

EKG-Respiration Unit |

  • ATTiny85 NeoPixel Token
  • EXG BIO AMP Unit
  • Respiration Detection Sensor with Amplifier
  • Harness
  • RJ45 Socket Breakout Board

|

Pin Mapping
Line # Device Signal Function
1 3.3V Power
2 GND Power
3 NeoPixel Controller I2C-SDA
4 NeoPixel Controller I2C-SCL
5 Respiration Detection Analog
6 Respiration Detection Adjust Analog
7 N/C Analog
8 Heart Beat Signal Analog

|