Difference between revisions of "Pseudo-Medical Monitor Tracking Goggles External Unit Design"
(47 intermediate revisions by the same user not shown) | |||
Line 51: | Line 51: | ||
|- | |- | ||
|8 | |8 | ||
− | | | + | |BNO055_INT |
− | | | + | |Analog3 |
|} | |} | ||
| | | | ||
Line 75: | Line 75: | ||
| | | | ||
Sensor and Face mounting | Sensor and Face mounting | ||
+ | |- | ||
+ | | | ||
+ | [[File:JAC_MED_MON_GOGGLES_SIMPLE_DRIVER.jpg|left|thumbnail|x200px]] | ||
+ | IR Sensor Driver and Sensing Board | ||
+ | | | ||
+ | Provide power to IR sensors and path for return signals | ||
+ | |- | ||
+ | | | ||
+ | [[File:JAC_MED_MON_TRACKING_GOGGLES_CABLE_SOCKET.jpg|left|thumbnail|x200px]] | ||
+ | Goggle Connection Cable Socket | ||
+ | | | ||
+ | Connects Goggles to driver box | ||
+ | |- | ||
+ | | | ||
+ | [[File:JAC_MED_MON_BNO055_SOCKET.jpg|left|thumbnail|x200px]] | ||
+ | BNO055 Sensor Module Socket | ||
+ | | | ||
+ | Mounting point for Google orientation sensor | ||
|- | |- | ||
| | | | ||
Line 81: | Line 99: | ||
| | | | ||
Provide External Unit ID to Main Unit | Provide External Unit ID to Main Unit | ||
+ | |- | ||
+ | | | ||
+ | [[File:JAC_MED_MON_RIBBON_CABLE_PART.jpg|left|thumbnail|x200px]] | ||
+ | 16 Conductor Ribbon Cable | ||
+ | | | ||
+ | * Connect Googles to driver box | ||
+ | * Reduced line counts used as cabling | ||
|- | |- | ||
| | | | ||
Line 87: | Line 112: | ||
| | | | ||
Provide connectivity to the Main Device | Provide connectivity to the Main Device | ||
+ | |- | ||
+ | | | ||
+ | [[File:JAC MED MON HEADER PARTS.jpg|left|thumbnail|x200px]] | ||
+ | Headers | ||
+ | | | ||
+ | Provide connections between items | ||
|- | |- | ||
| | | | ||
Line 94: | Line 125: | ||
Filter Ambient IR from sensors | Filter Ambient IR from sensors | ||
|- | |- | ||
+ | | | ||
+ | [[File:JAC MED MON FOAM SHEET MATERIAL.jpg|left|thumbnail|x200px]] | ||
+ | Foam Sheet | ||
+ | | | ||
+ | Used for mounting IR filter to goggles | ||
+ | |- | ||
+ | | | ||
+ | [[File:JAC_MED_MON_PROJECT_BOX_RS.jpg|left|thumbnail|x200px]] | ||
+ | Project Box (variants) | ||
+ | | | ||
+ | Enclosure | ||
+ | |} | ||
+ | |||
+ | === Sensors === | ||
+ | |||
+ | {|class="wikitable" | ||
+ | !colspan="3"|Sensors | ||
+ | |- | ||
+ | |Device | ||
+ | |Description | ||
+ | |Interface | ||
+ | |- | ||
+ | | | ||
+ | [[File:JAC_MED_MON_TCRT5000_PART.jpg|left|thumbnail|x200px]] | ||
+ | TCRT5000 | ||
+ | | | ||
+ | IR Reflectance Sensor | ||
+ | | | ||
+ | Analog Voltage Output | ||
+ | |- | ||
+ | | | ||
+ | [[File:JAC_MED_MON_BNO055_PART.jpg|left|thumbnail|x200px]] | ||
+ | BNO055 Absolute Orientation Sensor | ||
+ | | | ||
+ | Provides direction of Goggle's line of sight | ||
+ | | | ||
+ | I2C Address 0x28 | ||
|} | |} | ||
+ | |||
+ | === Wiring === | ||
+ | |||
+ | {|class="wikitable" | ||
+ | !colspan="3"| | ||
+ | |- | ||
+ | |Sub-Assembly | ||
+ | |Elements | ||
+ | |Schematic | ||
+ | |- | ||
+ | | | ||
+ | [[File:JAC MED MON GOGGLES SIMPLE DRIVER.jpg|left|thumbnail|x200px]] | ||
+ | | | ||
+ | * IR LED brightness Adjustment | ||
+ | * IR Receiver Signal | ||
+ | | | ||
+ | [[File:JAC_MED_MON_GOGGLES_SIMPLE_SCHEMATIC.jpg|left|thumbnail|x200px]] | ||
+ | |- | ||
+ | | | ||
+ | [[File:JAC_MED_MON_TRACKING_GOGGLES_UNIT_WHOLE.jpg|left|thumbnail|x200px]] | ||
+ | | | ||
+ | * Three IR Emitter/Receiver Sets | ||
+ | * BNO055 Orientation Sensor | ||
+ | * ATTiny85 Token | ||
+ | | | ||
+ | [[File:JAC_MED_MON_TRACKING_GOGGLES_SCHEMATIC.jpg|left|thumbnail|x200px]] | ||
+ | |} | ||
+ | |||
+ | === Assembly === | ||
+ | |||
+ | ==== Tracking Goggles ==== | ||
+ | |||
+ | {|class="wikitable" | ||
+ | !colspan="3"| | ||
+ | |- | ||
+ | |Sub-Assembly | ||
+ | |Elements | ||
+ | |- | ||
+ | |rowspan="8"| | ||
+ | [[File:JAC_MED_MON_GOGGLES_6.jpg|left|thumbnail|x200px]] | ||
+ | |- | ||
+ | | | ||
+ | [[File:JAC MED MON GOGGLE PART.jpg|left|thumbnail|x200px]] | ||
+ | |- | ||
+ | | | ||
+ | [[File:JAC MED MON TCRT5000 PART.jpg|left|thumbnail|x200px]] | ||
+ | |- | ||
+ | | | ||
+ | [[File:JAC MED MON FOAM SHEET MATERIAL.jpg|left|thumbnail|x200px]] | ||
+ | |- | ||
+ | | | ||
+ | [[File:JAC MED MON IR FILTER MATERIAL.jpg|left|thumbnail|x200px]] | ||
+ | |- | ||
+ | | | ||
+ | [[File:JAC MED MON TRACKING GOGGLES CABLE SOCKET.jpg|left|thumbnail|x200px]] | ||
+ | |- | ||
+ | | | ||
+ | [[File:JAC MED MON BNO055 SOCKET.jpg|left|thumbnail|x200px]] | ||
+ | |- | ||
+ | | | ||
+ | [[File:JAC MED MON BNO055 PART.jpg|left|thumbnail|x200px]] | ||
+ | |} | ||
+ | |||
+ | ==== Control Box ==== | ||
+ | |||
+ | {|class="wikitable" | ||
+ | !colspan="3"| | ||
+ | |- | ||
+ | |Sub-Assembly | ||
+ | |Elements | ||
+ | |- | ||
+ | |rowspan="4"| | ||
+ | [[File:JAC_MED_MON_TRACKING_GOGGLES_CONTROL_BOX.jpg|left|thumbnail|x200px]] | ||
+ | |- | ||
+ | | | ||
+ | [[File:JAC MED MON GOGGLES SIMPLE DRIVER.jpg|left|thumbnail|x200px]] | ||
+ | |- | ||
+ | | | ||
+ | [[File:JAC MED MON ATTINY85 TOKEN BOX.jpg|left|thumbnail|x200px]] | ||
+ | |- | ||
+ | | | ||
+ | [[File:JAC MED MON RJ45 SINGLE PART.jpg|left|thumbnail|x200px]] | ||
+ | |} | ||
+ | |||
+ | ==== Total ==== | ||
+ | |||
+ | [[File:JAC MED MON TRACKING GOGGLES UNIT WHOLE.jpg]] | ||
+ | |||
+ | == BUILD == | ||
+ | |||
+ | [[File:JAC MED MON GOGGLES SIMPLE DRIVER.jpg]] | ||
+ | |||
+ | [[File:JAC MED MON GOGGLES SIMPLE DRIVER BOXED.jpg]] | ||
+ | |||
+ | [[File:JAC MED MON GOGGLES 1.jpg]] | ||
+ | |||
+ | [[File:JAC MED MON GOGGLES 2.jpg]] | ||
+ | |||
+ | [[File:JAC MED MON GOGGLES MPU.jpg]] MPU Replaced with IMU | ||
+ | |||
+ | [[File:JAC MED MON GOGGLES SIMPLE UNIT.jpg]] | ||
+ | |||
+ | [[File:JAC MED MON GOGGLES 3.jpg]] | ||
+ | |||
+ | [[File:JAC MED MON GOGGLES 4.jpg]] | ||
+ | |||
+ | [[File:JAC MED MON GOGGLES 5.jpg]] | ||
+ | |||
+ | [[File:JAC MED MON GOGGLES 6.jpg]] | ||
+ | |||
+ | [[File:JAC MED MON GOGGLES 7.jpg]] | ||
+ | |||
+ | == Return == | ||
+ | |||
+ | [[Pseudo-Medical Monitor]] |
Latest revision as of 11:10, 11 December 2021
UNIT | ||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Device | Interactions | Port Description | Connection Diagram | |||||||||||||||||||||||||||||||
Tracking Goggles Unit |
|
|
This Amazing, Affordable, Earth Changing Device, for which no endorsement is to be inferred, is designed opposing gravity.
Contents
Tracking Goggles External Unit
Components and Materials
Items | |
---|---|
Device | Use |
Goggles (variants used) |
Sensor and Face mounting |
IR Sensor Driver and Sensing Board |
Provide power to IR sensors and path for return signals |
Goggle Connection Cable Socket |
Connects Goggles to driver box |
BNO055 Sensor Module Socket |
Mounting point for Google orientation sensor |
ATTiny85 Identification Token |
Provide External Unit ID to Main Unit |
16 Conductor Ribbon Cable |
|
RJ45 Port (variants used) |
Provide connectivity to the Main Device |
Headers |
Provide connections between items |
IR Filter Semi-Transparent Film |
Filter Ambient IR from sensors |
Foam Sheet |
Used for mounting IR filter to goggles |
Project Box (variants) |
Enclosure |
Sensors
Sensors | ||
---|---|---|
Device | Description | Interface |
TCRT5000 |
IR Reflectance Sensor |
Analog Voltage Output |
BNO055 Absolute Orientation Sensor |
Provides direction of Goggle's line of sight |
I2C Address 0x28 |
Wiring
Sub-Assembly | Elements | Schematic |
|
||
|
Assembly
Tracking Goggles
Sub-Assembly | Elements | |
Control Box
Sub-Assembly | Elements | |
Total
BUILD
Return
Pseudo-Medical Monitor