Pseudo-Medical Monitor Hand-Held External Unit Design: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
|||
| Line 82: | Line 82: | ||
| | | | ||
Provide sensory input to user | Provide sensory input to user | ||
|- | |||
| | |||
[[File:JAC MED MON ATTINY85 TOKEN BARE.jpg|left|thumbnail|x200px]] | |||
| ATTiny85 Token | |||
| | |||
Identify External Unit to Main Unit | |||
|- | |||
| | |||
[[File:JAC_MED_MON_RJ45_SINGLE_BARE_PART.jpg|left|thumbnail|x200px]] | |||
| Single RJ45 Port | |||
| | |||
Connection to Main Unit | |||
|- | |- | ||
| | | | ||
| Line 94: | Line 106: | ||
| | | | ||
Conductive surface for Velostat sheet readings | Conductive surface for Velostat sheet readings | ||
|- | |- | ||
| | | | ||
Revision as of 15:17, 10 December 2021
This Amazing, Affordable, Earth Changing Device, for which no endorsement is to be inferred, is designed as a shot in the dark.
Hand-Held Grip and Reflex External Unit
Components and Materials
| General Components | ||
|---|---|---|
| Device | Name | Use |
|
|
Momentary Switch |
Provide user response |
|
|
Vibrating Motor |
Provide sensory input to user |
|
|
ATTiny85 Token |
Identify External Unit to Main Unit |
|
|
Single RJ45 Port |
Connection to Main Unit |
|
|
Foam Sheet |
Outer Cover |
|
|
Copper Tape |
Conductive surface for Velostat sheet readings |
|
|
Polycarbonate Tube (Size/Length/Diameter/Thickness varied according to use) |
Grip Structure |
Sensors
| Sensors | |||
|---|---|---|---|
| Device | Name | Description | Interface |
|
|
MPU6050 6 DOF Micro Electro-Mechanical Systems (MEMS) | 3-axis Accelerometer and 3-axis Gyroscope | I2C Address 0x68 or 0x69 |
|
|
Velostat Pressure-Sensitive Conductive Sheet | Resistance measurement between points | |
Wiring
| Sub-Assembly | Elements | Schematic |
Hand Held Unit PCB |
|
|