Campbell Hausfeld Air Compressor: Difference between revisions

From LVL1
Jump to navigation Jump to search
JimD (talk | contribs)
No edit summary
JimD (talk | contribs)
No edit summary
Line 9: Line 9:
|picture=CampbellHausfeldAirCompressor.JPG
|picture=CampbellHausfeldAirCompressor.JPG
}}
}}
== This is a work in progress ==
== Operation ==
Generally
The air compressor provides on-demand compressed air to outlet locations in the space for utility use.  It is typically left powered on (enabled), all the time.  Be aware that it can unexpectedly start at any time.  The tank pressure is typically maintained at 125 psig.  When the tank pressure falls below a low-pressure set point, the unit's electric motor automatically starts to operate the compressor to rebuild/restore the tank pressure.  When the tank pressure reaches a high-pressure set point, the electric motor automatically turns off, stopping the compressor.  It remains enabled to automatically re-setart as needed to maintain tank pressure.


'''How to Turn it On'''
'''How to Turn it On (Enabled)'''
Notice the red selector switch. Turn it from off to on.  This will enable the automatic operation based on tank pressure
 
== Safety ==
* Realize the enabled air compressor electric motor can and will automatically start at any time.  Avoid entangling body parts in the (potentially) rotating machinery.
* Realize the compressed air in the tank is an energy source, even after electric power is removed.  Vent the tank to atmospheric pressure before servicing to release this energy source.
* Realize the compressed air in the lines and at outlet locations is an energy source.  Use caution when making connections and initiating flow to avoid unintended consequences. 
* Compressed air is typically used to blow sawdust, metal chips, and dust from the equipment.  Wear PPE (eye and ear protection) to avoid injury from contact with such debris.


== Maintenance ==
== Maintenance ==
Line 19: Line 26:


'''Drain waste water condensate from the tank'''
'''Drain waste water condensate from the tank'''
* Eye wear
Atmospheric air contains invisible moisture.  When atmospheric air is compressed, the physics of pressure and temperature changes can cause this moisture to condense from the air as liquid water.  This
* Secure  
* Secure  
* Loose
* Loose
Line 36: Line 43:


[[File:DSC 7250.JPG|200px]]
[[File:DSC 7250.JPG|200px]]
To know what speed to run the mill you must know:
* The type of material
* The type of cutter

Revision as of 09:35, 24 December 2019

Back to list of Equipment

Campbell_Hausfeld_Air_Compressor&.png

Equipment Overview

  • Owner/Loaner: LVL1
  • Serial Number: JB 1775139
  • Make/Model: Campbell Hausfeld
  • Arrival Date: circa new space
  • Usability: Yes
  • Contact: David Ortiz-Grob, Jim Kidwell
  • Where: Metal Shop, back left corner


Operation

The air compressor provides on-demand compressed air to outlet locations in the space for utility use. It is typically left powered on (enabled), all the time. Be aware that it can unexpectedly start at any time. The tank pressure is typically maintained at 125 psig. When the tank pressure falls below a low-pressure set point, the unit's electric motor automatically starts to operate the compressor to rebuild/restore the tank pressure. When the tank pressure reaches a high-pressure set point, the electric motor automatically turns off, stopping the compressor. It remains enabled to automatically re-setart as needed to maintain tank pressure.

How to Turn it On (Enabled) Notice the red selector switch. Turn it from off to on. This will enable the automatic operation based on tank pressure

Safety

  • Realize the enabled air compressor electric motor can and will automatically start at any time. Avoid entangling body parts in the (potentially) rotating machinery.
  • Realize the compressed air in the tank is an energy source, even after electric power is removed. Vent the tank to atmospheric pressure before servicing to release this energy source.
  • Realize the compressed air in the lines and at outlet locations is an energy source. Use caution when making connections and initiating flow to avoid unintended consequences.
  • Compressed air is typically used to blow sawdust, metal chips, and dust from the equipment. Wear PPE (eye and ear protection) to avoid injury from contact with such debris.

Maintenance

The following should be done

Drain waste water condensate from the tank Atmospheric air contains invisible moisture. When atmospheric air is compressed, the physics of pressure and temperature changes can cause this moisture to condense from the air as liquid water. This

  • Secure
  • Loose
  • Do not

Change the oil in the air compressor

  • Eye wear
  • Secure
  • Loose
  • Do not

Cutting Speed

The speed File:HY02D223B.pdf is a PDF of the VFD owner's manual, that may be useful to change the settings for the VFD