Radiation is all around.  And the Truely Mad Scientist's LVL1 Splinter Group wants to detect it all.  For this build, the readiation being detected is alpha radiation.  Alpha radiation consists of alpha particles ejected from a decaying atom.  The particle consists of two protons and two neutrons.  The particle is essentially a helium atom nuclei and carries a positive charge.  The positive charge allows for its identification and detection.
 
Radiation is all around.  And the Truely Mad Scientist's LVL1 Splinter Group wants to detect it all.  For this build, the readiation being detected is alpha radiation.  Alpha radiation consists of alpha particles ejected from a decaying atom.  The particle consists of two protons and two neutrons.  The particle is essentially a helium atom nuclei and carries a positive charge.  The positive charge allows for its identification and detection.
  
 +
== The Build ==
  
 +
===The Bill of Materials:===
 +
* Thin Copper Wire
 +
* Single Row Header Pins
 +
* Stirring Straws
 +
* Strip Board
 +
* Acrylic Sheet (0.093, 0.22, 0.05 inches thicknesses)
 +
* Copper Sheet
 +
* 0.01 uf Ceramic Disc Capacitor 2kv rating (qty 2)
 +
* 1N4007 Diode (qty 12)
 +
* 1 watt 10 Mega Ohm Resistor
 +
* Power Supply CCFL Case MOD Lights
 +
* Hardboard
 +
* Wire
 +
* Nuts and Bolts
 +
* Super Glue
 +
* Hot Glue
  
  

Revision as of 14:18, 10 October 2012

Why

Radiation is all around. And the Truely Mad Scientist's LVL1 Splinter Group wants to detect it all. For this build, the readiation being detected is alpha radiation. Alpha radiation consists of alpha particles ejected from a decaying atom. The particle consists of two protons and two neutrons. The particle is essentially a helium atom nuclei and carries a positive charge. The positive charge allows for its identification and detection.

The Build

The Bill of Materials:

  • Thin Copper Wire
  • Single Row Header Pins
  • Stirring Straws
  • Strip Board
  • Acrylic Sheet (0.093, 0.22, 0.05 inches thicknesses)
  • Copper Sheet
  • 0.01 uf Ceramic Disc Capacitor 2kv rating (qty 2)
  • 1N4007 Diode (qty 12)
  • 1 watt 10 Mega Ohm Resistor
  • Power Supply CCFL Case MOD Lights
  • Hardboard
  • Wire
  • Nuts and Bolts
  • Super Glue
  • Hot Glue


Tms Exploded Sensor Plate.jpg

The Sensor Plate illustrated above is assembled in layers. The top layer consists of header pin spacers which are used to hold the sensor wires inplace. The sensor wires are wirewrapped to rows of header pin posts. Below the wires are straws which will tension the wire when assembled. This wire assembly is soldered onto a strip board with a square cut out of the center to allow the bottom elements to be adjusted in height and leveling. The bottom assembly begins with a Cover Plate designed to shield the Copper Plate's corner which collect charge and interfer with the operation. The Copper Plate is mounted on a space with a through hole to allow the Negative Voltage Wire to be attached. The Leveling Plate also has an access hole for the Negative Voltage Wire and serves as the mounting for the bottom assembly. Not visible in the diagram are the four leveling screws through the Strip Board and fastened to the Leveling Plate with springs between.

Sensor Plate.jpg

This assembled diagram shows the straws, flattened by the wires, providing tension.